Planning Ventilation for a New Restaurant: What to Sort Out Early

By the Freshvent team · · 6 min read

Row of canopy exhaust hoods above a restaurant cooking area

On a new restaurant fit-out, ventilation is often one of the last things anyone talks about. The interiors are chosen, the menu is ready, the equipment is ordered, and then someone asks where the exhaust duct is going to go. By then the options are limited and the fix is usually expensive.

Having worked on many of these projects, these are the things we wish every owner sorted out at the very beginning.

Fix the kitchen layout first

We cannot design a good exhaust system until we know where every piece of cooking equipment sits. Moving a tandoor or a fryer bank after the hood is made means changing the hood. Get the equipment layout signed off, then plan the ventilation around it.

Work out the duct route before the ceiling goes in

The duct has to travel from the hood to the outside, ideally in the shortest and straightest path possible. Every bend adds resistance and makes the fan work harder. In malls and commercial buildings, there may be a fixed shaft you have to connect to, with rules from the building management about size and fire protection.

Walk the route with your contractor while the ceiling is still open. Check for beams, AC ducts, sprinkler lines and plumbing that might get in the way.

Decide where the exhaust fan will sit

The fan is usually placed at the end of the duct, on the roof or an outside wall, so the duct stays under negative pressure and smoke does not leak into the building. It needs to be reachable for servicing, and it should not blow straight into a neighbour's window or a public walkway. Sorting this out early avoids complaints later.

Do not forget fresh air

Every bit of air the exhaust pulls out has to be replaced. If it is not, the kitchen ends up under strong negative pressure: doors become hard to open, the hood performs badly, and hot air and smells get dragged in from wherever they can. A planned fresh air supply keeps the kitchen comfortable and helps the exhaust do its job.

Bring the electrician into the conversation

Fans, lighting in the hood, control panels and any speed controllers all need power in the right place. When the mechanical and electrical teams work separately, you end up with cables in the wrong spot and a panel nobody can reach. This is one of the main reasons we handle both mechanical and electrical work ourselves: one team, one plan.

Leave time for testing

A system is not finished when the last bolt goes in. It needs to be switched on, checked for airflow, checked for leaks and noise, and adjusted before you start cooking for customers. Please do not plan your opening day for the day after installation. Give yourself a few days of buffer.

Order of work that tends to go smoothly: confirm the kitchen layout, survey the duct route, fabricate the duct and hood, install them, connect the electricals, then test and commission. When those steps happen in order, fit-outs run on time far more often.

If you are at the early stages of a new restaurant or cloud kitchen, talk to us before the ceiling goes in. A short site visit at the right time can save a lot of rework.

← Back to all articles

Planning a Commercial Kitchen Project?

Tell us about your kitchen and we will get back to you with the next steps.